Our Technology

A company that values the environment

Evaporation · Concentration

Expected utility consumption by type

Comparison of utility requirements in the form of ME, TVR, MVR per ton of evaporation
Concentration system type Utility requirement (when 1 ton of waste water is evaporated)
Type Number of stage Steam consumption(kg/ton) Power consumption(kwh/ton) City Water consumption(kg/ton)
ME 1 Effect 1,200 – 1,300 16 -20 1,800 – 1,950
2 Effect 630 - 670 18 -22 945 – 1,005
3 Effect 400 – 450 20 -24 600 - 675
4 Effect 300 - 320 22 -26 450 - 480
5 Effect 240 - 260 24 - 28 360 - 390
TVR 1 Effect 450 - 550 16 - 20 675 - 825
2 Effect 320 - 400 18 - 22 480 - 600
3 Effect 175 - 300 20 - 24 262 - 450
4 Effect 150 - 230 22 - 26 225 - 345
5 Effect 130 - 170 24 - 28 195 - 255
MVR 1 Effect 50 - 60 30 - 40 75 - 90
2 Effect 20 - 40 32 - 42 30 - 60
3 Effect 10 -30 34 - 44 15 - 45